All products:
RoHS & CE

  Home    Specification     Health     General     Installation     Efficiency      Contact Us     



Shopping line
Shopping line

Selection Help
at your service

Product In-ine fans

Product HRV-Solar & PWM-Soalr
Product Ultra Plus & Ultra
Product PowerPLus & Power
--- Welcome to FAHRenergy Web Shop ---
Selecting the best HRV
FAHRenergy Shop

Shopping line

a 
  FAHRenergy Ultra+ and Ultra Heat Recovery Ventilators  
Patented

Ultra Plus Heat Recovery Ventilator 200m3/h
Ultra HRV 200m3/h


    FAHRenergy Ultra+ HRV
Intended for tougher environments.
The insulated aluminium casing
protects the Ultra HRV.




UltraPlus & Ultra specification

FAHRenergy Ultra Series In-Brief
1. Counter-Flow with Linear Breakers
2. 200m3 of heat recovered fresh air per hour
3. Energy recovery to 80% per year
4. 12VDC / 54W
5. Power supply: 110 to 230Vac
6. 125mm duct connections
7. CoP ~ 17

Contact Us

 FMP saved
25000 kWh 
The Ultra series is intended for
Light-Industry
Offices
Green houses
Staples
Welding fume extraction
Garages
 To select a product, click the picture
Perform: Select Product    Select Payment


 Click for proof

Patented
 To select a product, click the picture



Power+, Power Plus
  FAHRenergy Power+ and Power Heat Recovery Ventilators  

FAHRenergy Power HRV 2011

   FAHRenergy Power+ HRV
Intended for tougher environments.
The insulated aluminium casing
protects the Power HRV.
Patented
Get specification for Power



   FAHRenergy Power HRV
Our low cost Power version

Attachment bracket allows for
easy maintenance and inspectioin

Get specification for Power
The Power Series is intended for
Existing homes
New homes
Conservatories
Moisture extraction
Radon mitigation
Garages
FAHRenergy Power Series In-Brief
1. Counter-Flow with Linear Breakers
2. 90m3 of heat recovered fresh air per hour
3. Energy recovery to 80% per year
4. 12VDC / 18W
5. Power supply: 110 to 230Vac
6. Power+ = 125mm duct connections
7. Power = 100mm duct connections
7. CoP ~ 20
Specification for Power+ and Power


 FAHRenergy HRV-Solar and PWM-Solar
Installation
examples


Get instalaltion examples








Solar powered HRV, FTX
Get specification for Power
Shopping line

Shopping line

Get specification for Power



FAHRenergy Ultra In-Line axial fan 12VDC/24W


Get specification for Power

Pulse Width Modulated solar panel charge unit

Specification for PWM-Solar









FAHRenergy Power In-Line axial fan 12VDC/7W


FAHRenergy Beserk In-Line fan for industry

Specification for Ultra Fan


Specification for Power Fan
Get specification for PowerGet specification for Power




Get specification for Power



 FAHRenergy Berserk HRV. Industrial fumes extraction.
 To select a product, click the picture




HRV / FTX for industrial fumes extraction and large rooms



    FAHRenergy Berserk HRV
High volume, high pressure makes this
HRV / FTX well suited for extraction of
industrial fumes from welding and more.

The new improved Berserk corresponds
to around 1200m³/h old style fume extraction.




Specification for Berserk HRV
Berserk Cyclone Filter
The Berserk cyclone filter
removes particles which
could damage the
Berserk HRV

Beserk HRV / FTX Cyclone filter



Two years field test down to -25°C in Sweden.

FAHRenergy Berserk HRV / FTX has been
field tested since 2009 at the swedish welding company
Floby Metallprodukter. More at this link:
http://www.flobymetallprodukter.se/Energireduktion2.html


FAHRenergy patent

Berserk HRV / FTX was installed November 2010
INtelliKable Solar Shop link

FAHRenergy Berserk HRV / FTX In-Brief
1. Counter-Flow with Linear Breakers
2. To 450m³ of heat recovered fresh air per hour
3. To 450m³ of extracted fumes per hour
4. For welding fume extraction:
    Energy savings to 85% per year (~25000kWh/year)
5. Power supply: 230Vac / 170W
6. 125mm duct connections

The Berserk is intended for
Welding fume extraction with energy savings and recovery
Other industrial fume extraction
 Copyright© FAHRenergy 2005 - 2012
                All Rights Reserved
Specification for Berserk Fan
FAHRenergy In-Line fans are especially
vaulable where space and/or low energy
is important
FAHRenergy In-Line Fans In-Brief
Berserk: 440m3/h, 110 to 240Vac
125mm ducts

Ultra: 320m3/h, 110 to 240Vac
125mm ducts

Power: 225m3/h, 100 to 240Vac
100mm ducts
FAHRenergy
Berserk In-Line Fan.
Very powerfull for its
small size and light weight
FAHRenergy
Power In-Line Fan

For tight spaces in industry.
Light weight
FAHRenergy
Ultra In-Line Fan

For tight spaces in industry.
Light weight
 To select a product, click the picture
FAHRenergy In-Line fans
HRV-Solar is intended for
Summer house
Caravan
Mobil home
Quiet rooms
FAHRenergy HRV-Solar In-Brief
1. Counter-Flow with Linear Breakers
2. 60 m3 of heat recovered fresh air per hour
3. Energy recovery to 80% per year
4. 12VDC / 6w
5. Quite mode: 4w (needs PWM-Solar)
6. 100 mm duct connections
7. CoP ~ 25
Connect PWM-Solar
to a caravan
Specification for HRV-Solar
  FAHRenergy PWM-Solar
Necessary to supply the HRV-Solar
from a solar panel. 90% efficiency.
  FAHRenergy HRV-Solar
For caravan and summerhouse.
Light weight and small enough
to fit a mobile home.
 To select a product, click the picture
 Products:
Specification for Ultra+ and Ultra
   FAHRenergy Ultra HRV
Our low cost Ultra version

Attachment brackets allows for
easy maintenance and inspection
FAHRenergy Banner